Skip to main content

Table 3 Probable cause of SNHL and pattern of audiogram

From: Discussion and expostulations on postoperative worsening of hearing following middle ear surgeries

Case no.

Disease

Treatment

Probable cause of SNHL

Post-op pattern of audiometry

1

COM squamous

ICW mastoidectomy with type III tympanoplasty

Disease clearance/manipulation/drilling

High frequency loss, right sloping curve

2

COM squamous

ICW mastoidectomy with type III tympanoplasty

Manipulation

High frequency

3

COM Mucosal

CM with type III tympanoplasty

? otorrhoea

All frequencies involved, flat curve

4

COM squamous

Modified radical mastoidectomy

Disease clearance/drilling

All frequencies, tinnitus

5

COM granulations with tympanosclerosis

Modified radical mastoidectomy

Ossicular manipulation

High frequencies

6

COM squamous

Type III tympanoplasty with TORP

Ossicular manipulation

High frequencies, tinnitus

7

COM squamous

ICW mastoidectomy with type III tympanoplasty

Unexplained

High frequency

8

COM mucosal

ICW mastoidectomy with type I tympanoplasty

??? infection

All frequencies