Table 6 Comparison between the two studied groups according to suppression value in TEOAE amplitudes (dB SPL)

From: Otoacoustic emissions and contralateral suppression in tinnitus sufferers with normal hearing

Suppression value

Cases (n = 15)

Ears = 30

Control (n = 15)

Ears = 30

U

p

1000

    

 Min.–max.

0.0 to 11.0

1.0 to 8.0

424.50

0.703

 Mean ± SD.

3.97 ± 2.81

3.97 ± 1.87

 Median

3.0

4.0

1500

    

 Min.–max.

0.0 to 17.0

3.0 to 15.0

366.00

0.211

 Mean ± SD.

5.80 ± 4.87

6.20 ± 3.09

 Median

4.50

5.0

2000

    

 Min.–max.

0.0 to 15.0

-3.0 to 10.0

425.0

0.710

 Mean ± SD.

4.87 ± 3.66

4.73 ± 3.59

 Median

4.0

5.0

3000

    

 Min.–max.

0.0 to 7.0

3.0 to 16.0

17.00*

< 0.001*

 Mean ± SD.

2.53 ± 1.78

9.60 ± 3.11

 Median

2.50

9.0

4000

    

 Min.–max.

0.0 to 11.0

2.0 to 9.0

114.00*

< 0.001*

 Mean ± SD.

2.50 ± 2.19

5.47 ± 1.93

 Median

2.0

6.0

  1. U, p U and p values for Mann-Whitney test for comparing between the two groups
  2. *Statistically significant at p ≤ 0.05