From: Bilateral cochlear implantation: simultaneous versus sequential
 | Bilateral implant | Best implant | Second implant | |||
---|---|---|---|---|---|---|
 | In quiet (%) | In noise | In quiet (%) | In noise | In quiet (%) | In noise |
P1 | 68 | 56 | 60 | 48 | 56 | 40 |
P2 | 60 | 48 | 56 | 32 | 40 | 16 |
P3 | 60 | 44 | 56 | 36 | 40 | 20 |
P4 | 64 | 52 | 56 | 44 | 48 | 40 |
P5 | 68 | 52 | 64 | 40 | 56 | 36 |
P8 | 76 | 64 | 72 | 60 | 68 | 48 |
P11 | 72 | 68 | 68 | 56 | 68 | 52 |
P12 | 68 | 56 | 64 | 52 | 64 | 48 |