Table 2 Bonferroni pairwise comparison test results for comparison of latency parameters between different stimuli

From: Optimum stimulus for eliciting masseter vestibular-evoked myogenic potential: a comparative exploration with three different acoustic stimuli

 

P1 latency chirp

P1 latency tone burst

N1 latency chirp

N1 latency tone burst

P1 latency click

p < 0.05

p < 0.05

  

N1 latency click

  

p < 0.05

p < 0.05

P1 latency chirp

 

p < 0.05

  

N1 latency chirp

   

p < 0.05